Go to main content
93/130
90
SCLS-01000 to SCLS-01005
SCLS-01000: Failed to create super cluster representative server for tier {0}, {1}
Cause:
Failed to create super cluster representative server for the given tier.
Action:
Retry after resolving cause stated in message.
SCLS-01001: Failed to get ONS runtime of {0}
Cause:
Failed to get ONS runtime of the given server.
Action:
Retry after resolving cause stated in message.
SCLS-01002: Failed to get current member list of tier {0}
Cause:
Failed to get current member list of the given tier.
Action:
Retry after resolving cause stated in message.
SCLS-01003: eONS runtime was not running for tier {0}
Cause:
eONS runtime was stopped abnormally.
Action:
In cluster environment, try srvctl stop nodeapps -n <node> and srvctl start nodeapps -n <node>. In Oracle Restart environment, try srvctl stop eons and srvctl start eons.
SCLS-01004: Failed to set listening port to {0} for {1}
Cause:
Failed to update listening port of the eONS runtime for this tier.
Action:
Make sure that user has permission to update resource attribute. In cluster environment make sure that the clusterware stack is up.
SCLS-01005: Invalid listening port {0} specified for eONS
Cause:
The specified eONS listening port number is invalid.
Action:
Valid port numbers on Unix are from 1025 to 65535. Provide a valid port number for eONS to listen on.